Cathodic Protection Products - Off-Shore

Amstel for Off-Shore

We have Amstels available for windfarms in IP67 enclosures.

 

Amstels are also available in EX enclosures for zone 1 & 2 areas.

 


Products

ICCP Amstel 1 N (New version)

Range 6 to 50V  1 to 15A <400W

 

The Amstel 1 Type C is a compact and robust switch mode power supply, forced cooled, specifically designed for cathodic protection. Standard SCADA RS485 MODBUS fieldbus.

Read more ...

ICCP Amstel 1 N (replaced by a new type)

Range 6 to 50V  1 to 10A <200W

 

The Amstel 1 Type C is a compact and robust switch mode power supply, forced cooled, specifically designed for cathodic protection. Standard SCADA RS485 MODBUS fieldbus.

Read more ...

ICCP Amstel 2 N

Range 8 to 60V  5 to 30A <500W

 

The Amstel 2 Type C is a compact and robust switch mode power supply, natrual cooled, specifically designed for Cathodic protection on low maintenace application. Standard SCADA RS485 MODBUS fieldbus.

Read more ...

ICCP Amstel 3 F

 

Range 8 to 60V  40 to 200A <2500W

 

The Amstel 3 Type C is a compact and robust switch mode power supply, forced cooled, specifically designed for cathodic protection. Standard SCADA RS485 MODBUS fieldbus.

Read more ...

ICCP Amstel 3 N

 

Range 8 to 60V  10 to 60A <1000W

 

The Amstel 3 Type C is a compact and robust switch mode power supply, natural cooled, specifically designed for cathodic protection. Standard SCADA RS485 MODBUS fieldbus.

Read more ...

ICCP Amstel 4 F

 

Range 8V to 60V  80A to 500A <7500W

 

The Amstel 4 Type C is a compact and robust switch mode power supply, forced cooled, specifically designed for cathodic protection. Standard SCADA RS485 MODBUS fieldbus.

Read more ...

ICCP Amstel 4 N

 

Range 8...60V  15...100A <2000W

 

The Amstel 4 Type C is a compact and robust switch mode power supply, naterual cooled, specifically designed for cathodic protection. Standard SCADA RS485 MODBUS fieldbus.

Read more ...

Parameterization for Amstels

Parameterization software for Amstel devices. With this software all registers of the Amstels, or other devices related to the Amstel Rectifiers, can be parameterized. 

Read more ...

Options

  • AF1

    Reverse air flow, bottom to top direction. 

  • M1

    Menu controlled with push buttons on top.  

  • PU1

    Cathodic protection Timer option.

  • RF1

    Cathodic protection potential controlled on ON value reference cell can be any type as long the...

  • RF2

    Cathodic protection potential controlled on OFF value reference cell can be any type as long the...

  • RF3

    Cathodic protection potential controlled on ON and OFF value reference cell can be any type as...

  • RS1

    RS485 Modbus RTU/ASCII open protocol easy to integrate with SCADA or other controls PLC etc.

  • TB1

    Vertical mounting holes Top and Bottom

  • US1

    USB parameterization option.