Plating Industry - Products - PCB

P Amstel 3

 

Range 6 to 50V  50 to 200A <2500W

 

The Amstel 3 Type P is a compact and robust switch mode power supply, forced cooled, specifically designed for plating machines, full control by MODBUS.

 

The Amstel Rectifier is Voltage and Current constant. The rectifier can be parameterized by the AM software RS485 or RS232, and optionally parameterized using three push buttons by menu structure. The parameters can be protected by a PIN code to prevent unauthorized personnel to change settings.

Types 

Voltage

6V

8V

12V

16V

20V 

24V

30V

40V

50V

50A            
80A        
100A      
120A        
150A          
200A            
current                  

 

Features

  • Aux. supply: 190V...265V.
  • Line Power supply specified by customer: 200V/208V/220/340V/380V/400V/415V/440V/480V.
  • Modbus over RS485.
  • RTU and ASCII protocol.  1200...115.200 baud (19.200 baud default).
  • Contact failure detection.
  • Auto low voltage at no load.
  • Alarms on over-current, over-voltage. 

Control and Display Panel 

  • Display actual Current & Voltage display
  • Optional Menu
  • Status Leds

- Power LED 

- Communication LED

- Output active LED

- Error LED

  • RS232 DB9 female 

Connection panel

Power connector

  • Aux. power 190Vac..265Vac 1ph
  • Main power 3ph

Fieldbus

  • RS485 half duplex MODBUS

Input/Output

  • Actual Uout and Iout 0-60mVdc
  • Digital potential free output contact
  • 2x Digital inputs
  • 1x Digital output

DC output

  • Plus terminal M8 hole for cable lug
  • Min terminal M8 hole for cable lug 

Fuse for the auxiliary power supply

Standard air out, optional reversed airflow.

Specifications

 Item Minimal Nominal Maximal Unit
 Environment temperature -20 +20 +35 oC
 Relative humidity 10 60 90 %
 Height     192 mm
 Width     244 mm
 Length     353 mm
 Weight  8   11 kg
 Electrical        
 Line voltage [AC] depending on type -5% Line voltage +10% V
 Max output power (depending on type)     2500 W
 Standby power incl.   2   W
 Input fuse 5x20mm Slow   1.6   A
 Accuracy    <0.2   

PDN

PDN = AM3F-(DC Voltage)V-(DC Current)A-3-400V-P(Options)

Example

Amstel 3 20V 100A Forced cooled 3ph 400Vac with modbus and Menu

AM3F-20V-100A-3-400V-PM1RS1

Options

  • AF1

    Reverse air flow, bottom to top direction. 

  • M1

    Basic menu control for Amstels.

  • PR1

    Polar change with contactors.

  • PR2

    Cathodic protection menu control for Amstels.

  • PR3

    Polar electronic change over by mosfets .

  • PU1

    Interrupt plating.

  • PU2

    Forward Pulse output (Chopper).

  • RS1

    RS485 Modbus RTU/ASCII open protocol easy to integrate with SCADA or other controls PLC etc.

  • TB1

    Vertical mounting holes Top and Bottom

  • US1

    USB parameterization option.